Sho-Rate™ Series Glass Tube Variable Area Flow Meters

Proven performance for low flow rates. Versatile options to match your needs.
Models 1250A / 1255A / 1350G / 1355G / 1358

For a wide range of chemical, petrochemical, biotechnology, research and analytical applications, Sho-Rate™ Series glass tube variable area flow meters provide industry-leading repeatability and reliability in two versatile lines.

Sho-Rate™ 1350/1355 flow meters deliver up to 3% accuracy and 0.25% repeatability depending on the model. Sho-Rate™ 1250/1255 flow meters offer a durable, cost-effective design to meet OEM requirements for systems requiring metering and analyzer integrators.

Questions?

Talk to one of our application engineering experts by calling: 1-888-554-3569


For pricing information:

Request a Quote
Sho-Rate™ Series Data Sheet

Features

  • Flow Ranges:
    • Air: Up to 140 scfh / 63 slpm
    • Water: Up to 34 gph / 2000 cc/min
  • Borosilicate glass tubes are compatible with most gases and fluids
  • Float materials include black glass, 316 stainless steel, sapphire, Carboloy®, tantalum
  • Magnification ensures scales are easy to read

Sho-Rate™ 1350 / 1355 / 1358 features include:

  • Three accuracy levels: 3% (low-flow Model 1355), 5% (low-flow Model 1350) or standard accuracy of 10% (high-flow Model 1358)
  • Repeatability of 0.25% Full Scale (0.5% Full Scale for Model 1358)
  • Scale includes built-in magnifier – scale decals can be applied directly to the tube to support unique flow ranges and units of measure
  • Optional standard or NRS™ integral needle control valves, as well as flow controllers on the inlet or outlet to go beyond measurement
  • Integrated alarm option with single or double inductive ring sensor/switch with Intrinsically Safe Relay is ideal for hazardous environments

Sho-Rate™ 1250 / 1255 features include:

  • Two accuracy levels: 5% Full Scale (Model 1250), 3% Full Scale (Model 1255)
  • Standard direct-read scales for common units and fluids – 65 mm, 150 mm scale lengths (approximate)
  • Inlet valve and outlet valve with options of cartridge valve, precision control valve or no valve
  • Easy-change design allows quick interchangeability of tube assemblies
  • Rotating lens provides a 180° view with magnification

Benefits

  • Options offer value-added features to meet project or OEM requirements
  • Borosilicate glass is resistant to thermal shock and corrosive gases and fluids
  • Corrosion-resistant material options for scales, floats, fittings and valves accommodate demanding applications
  • Integral float stops prevent loss of float during tube removal
  • Enhance accuracy with easy-to-read scales with magnification
  • Adjustable alarm guarantees safety and continuous process monitoring

Applications

  • Pharmaceutical production
  • Research
  • Chemical manufacturing
  • Analytical instrumentation
  • Water treatment and distribution systems

{A505A882-BA63-4808-B82D-CBF9E105604B}
Product Type

Glass Tube VA Flow Meter

 

{FAE4237D-0950-4F7B-B6F4-FAD8931DE1F9}
Differentiator

Ideal for Wide Variety of Gas & Liquid Applications

Economical

Optional Integrated single or double alarm

QuickShip Available

{34C8F0E3-95ED-4BFA-A368-8DC9E3F778C0}
Performance
{FDBA13EE-5F2D-46E3-8EDA-A7089A04BB48}
Flow Range (Full Scale Capacity)

Water

0.8 - 5 gpm

0.01 - 34 gph

0.041 - 130 lph



Air

3.4 - 15 scfm

0.12 - 140 scfh

3.2 - 3700 nlph

Nitrogen

4-900 ml/min

2-100 CCM

0.1-9 LPM

0.1-130 SCFH

{992FB906-1DB7-4DED-AA5C-6BF3BDC017F0}
Accuracy
± 3% - 10% FS
{98CCBAE6-795A-4625-B84D-C429DCEF01B1}
Repeatability
0.25% FS
{3142A94F-2FD7-48A0-84C8-F0FD7BEEBB72}
Ratings
{EC81C0B7-4ABF-4005-B1AC-32EA1A105B36}
Max Pressure
200 psig
{DC880E99-1607-49AA-919A-9CF875637F84}
Max Temperature
121oC (250oF)
{E35F1586-C865-455B-9F2F-84B7CF62D14A}
Mechanical
{2A69430C-86E9-4828-A675-09725BD69252}
Materials of Construction
Borosilicate Glass, Brass, Aluminum, 316 Stainless Steel, Clear Polycarbonate,
Milk White Polycarbonate, Teflon®
{873AE690-1C73-43BD-A3CD-47DAF71AD9E0}
Housing

Aluminum or Stainless Steel

 

{B1CA99FE-429A-47CF-A7B3-12185E24428C}
Metering Tube Material

Borosilicate Glass

 

{21114386-AC67-4F5F-8CE9-E38C72A610D3}
Scales

1250/1255

 Single or Dual Decal on Tube

1350/1355/1358

Single Decal on Tube

{91B4DEEC-D83F-4167-B069-99479CC3693F}
Scale Length
65mm, 150mm
{B25EDA44-6A59-437B-B8A6-0AABF281C848}
Scale Graduations
Choice of direct reading units, millimeter or percentage of maximum flow with factor tag.
{C0BE8AAB-F49A-4CC4-83F4-F83F964548C5}
Window Material

1350, 1355, 1358: Polycarbonate with UV Inhibitor

 

{6417C408-58F2-4155-9960-03CEAA6309EF}
Float Material
Carboloy®, Glass, Sapphire, Stainless Steel, Tantalum
{B8142038-59B0-4D9E-ACC4-748FF13DD8AF}
Float Stops
Teflon
{D6EF0977-C4F6-4D9E-BF2C-C76FC0E1D28F}
O-Ring Materials

Viton-A® fluoroelastomers

Buna-N

Teflon®

Butyl

EPR

Kalrez®

{02EA7C89-6551-4D93-AC0B-C60AB456BF5A}
Valve Options

Cartridge III Valve and NRS™

{1F34AA8C-3C85-4967-8982-C37E903229DB}
Valve Materials
Stainless Steel
{81DAEE70-D78C-4DD6-A20B-221DF5C5BFD0}
Flow Controller
Yes
{AD1B752C-E535-4F31-82CD-4E50B7146DAA}
End Block Options
Stainless Steel and Brass
{86B470FE-D4A6-46D6-BDF8-C5900F7D126B}
Connection Materials
Stainless Steel
{6359C85D-3076-457E-BD3E-2DF568D0AB03}
Process Connections

Horizontal female 3/8" NPT threaded adapters

1/8" - 1/4" NPT

1/8" - 1/4" Compression

6mm Compression

1/4" - 3/8"; RC

1/4" VCR®

1/4" Hose

Swagelok® Converters

{496D8792-02F2-4EA7-A256-7308A2CE0B45}
Diagnostics & Display
{D6CF62A7-39E8-4195-B841-26FC6EE6C7EF}
Alarms

Inductive ring sensor/switch

{7BCCBEBD-5E98-46EA-B623-D49C53783BB5}
Compliance
{BF905322-74D9-4786-970A-D564D3B7FD3F}
Certifications/Approvals
International Calibration Certificate (ICC)
1250A 1255A 1350G 1355G 1358
Differentiator Rotating lens allows 180° view with magnification Rotating lens allows 180° view with magnification

Clear Polycarbonate front shield with built-in magnifier for easy float and scale reading. Interchangeable tubes and floats with direct reading (DR) scales on tube

Clear Polycarbonate front shield with built-in magnifier for easy float and scale reading. Interchangeable tubes and floats with direct reading (DR) scales on tube

Heavy-wall, precision bore borosilicate glass metering tube. Tube removable without disconnecting the instrument.

Flow Range (Full Scale Capacity)
Millimeter Scale

Air (ccm)

50 - 65850 ccm*

Water (ccm)

21.4 - 2055 ccm*

*QuickShip
Millimeter Scale

Air (ccm)

50 - 66370 ccm*

Water (ccm)

22.2 - 2080 ccm*

*QuickShip
Millimeter Scale

See data sheet for ranges including QuickShip.

Millimeter Scale

See data sheet for ranges including QuickShip.

Millimeter Scale

See data sheet for ranges.

Flow Range (Full Scale Capacity)
Direct Read Scale
Water

.1 -10 lpm

.1 - 130 scfh

Air

.1 - 60 lpm

2 -550 ccm

.1 -25 scfh

Nitrogen

4-400 ml/min

0.1-1.2 scfh

Direct Read Scale
Water

.1 - 1.3 lpm

2 -130 ccm

Air

.05 - 50 lpm

4 - 850 ccm

.06 - 6 scfh

Nitrogen

2 - 100 ccm

0.1 - 9 lpm

.5 - 50 scfh
Direct Read Scale

Water

.010 - 34 gph

.041 - 130 lph

Air

.12 -140 scfh

3.2 - 3700 nlph

Direct Read Scale

Water

.59 - 2000 cc/min

Air

50 - 1300 scc/m

.82 - 63 slpm

Direct Read Scale

Water

.8 - 5 gpm

Air

3.4 - 15 scfm

Accuracy

± 5%

± 3%

± 5%

± 3%

± 10% FS

Materials of Construction

Borosilicate Glass

Aluminum

316 Stainless Steel

Clear Polycarbonate

Teflon

Borosilicate Glass

Aluminum

316 Stainless Steel

Clear Polycarbonate

Teflon

Borosilicate Glass

Brass

Aluminum

316 Stainless Steel

Clear Polycarbonate

Milk White Polycarbonate

Teflon

Borosilicate Glass

Brass

Aluminum

316 Stainless Steel

Clear Polycarbonate

Milk White Polycarbonate

Teflon

Borosilicate Glass
Filename File Type Documents By Language
Data Sheet - 1250/1255 pdf English
Data Sheet - 1350G/1355G pdf English French German Spanish
Data Sheet - 1358 pdf English
Installation & Operation Manual - 1250/1255 pdf English
Installation & Operation Manual - 1350G/1355G pdf English
Installation & Operation Manual - 1358 pdf English
CE EU Declaration of Conformity Certificate pdf English Korean Romanian Russian Spanish

Use the following guide (model code information from data sheet) to translate the CAD configurations available below. If you need assistance or can’t find what you’re looking for, please contact Applications Engineering or your local Brooks Instrument representative.

Example: 1350G - 1 - T - 1 - A

Meter Series
Fitting & Connection
Valve Connection Orientation Options
 1350G 1 - 316SS 1/4" Compression w/locknut (2 pc design)
T - Cartridge II/III Valve - Low Flow - 316SS
1 - Valve/Controller Location = Inlet, Connection Orientation = Back A - None
Cartridge Valves
Cartridge III Valve
NRS™ Needle Control Valves
NRS™ Needle Control Valves
FC Series
FC Series Manual Flow Controllers